Results: For participants in the top decile of environmental far-

Results: For participants in the top decile of environmental far-field RF-EMF exposure at baseline, in comparison to participants exposed below the median value, the change in the von Zerssen- and HIT-6-scores between baseline and follow-up was -0.12 (95%-CI: -1.79 to 1.56) and -0.37 (95%-CI: -1.80 to 1.07) units, respectively. Exposure to near-field sources and a change in exposure PCI-34051 manufacturer between baseline and follow-up were not related to non-specific symptoms. Similarly, no association between RF-EMF exposure and tinnitus was observed.

Conclusions: In this first cohort study using objective and well-validated RF-EMF exposure measures, we did not observe an

association between RF-EMF exposure and non-specific symptoms or tinnitus. (C) 2011 Elsevier Ltd. All rights reserved.”
“The aim of this study was to evaluate VX-765 the effectiveness of Chneau brace in the management of idiopathic scoliosis.

This is a retrospective observational study according to SOSORT

and SRS (Scoliosis Research Society) recommendations involving 48 girls with documented progressive idiopathic scoliosis, treated with Chneau brace. A statistical analysis was performed with STATA MP11.2 to validate the obtained results.

No patient needed surgery. The average curve angle measured in Cobb degrees passed from 27A degrees A A +/- A 6.7A degrees at the beginning (T0), to 7.6A degrees A A +/- A 7.4A degrees in brace (T1) (72 % of correction), to 8.5A degrees A A +/- A 8.6A degrees (69 % of correction) at the end of treatment (T2), to 11.0A degrees A A +/- A 7.4A degrees (59.3 % of correction) at final follow-up (mean 5 years and 5 months) (T3).

Conservative treatment with Chneau brace and physiotherapy was effective in our hands for halting scoliosis progression in 100 % of patients.”
“Background: Heart failure is a major public health problem. To improve grave prognosis. early identification of, Cardiac dysfunction is mandatory. Conventional echocardiography

is not suitable for this. Tissue Doppler imaging (TDI). however, could be so.

Methods and Results: Within a large community-based population-study (n = 1012), cardiac function was evaluated by conventional echocardiography (left ventricular hypertrophy, AZD1152 nmr dilatation, systolic, and severe diastolic dysfunction), TDI, and plasma proBNP. Averages of peak systolic (s’), early diastolic (e’), and late diastolic(a’) velocities from 6 mitral annular sites were used. TDI was furthermore quantified by a combined index (eas-index) of diastolic and systolic performance: e’/(a’ x s’). Compared with controls, persons with elevated plasma proBNP concentrations (n = 100) displayed lower systolic and diastolic performance by TDI, in terms of lower s’(P = 0.017) and a’ (P < .001), and higher e’/a’ (P = .002) and eas-index (P < .001).

Comments are closed.