We have shown that anterior condylar anatomy is highly variable r

We have shown that anterior condylar anatomy is highly variable regardless of sex. We believe that implants as well as surgical techniques should be designed with the variability of anterior condylar anatomy taken into account and with an attempt to reproduce such anatomy regardless of sex.”
“Background: Selleck BAY 1895344 With the availability of compact, portable, effective microspirometers, pulmonary function tests no longer need to be performed only in specialized laboratories. However, the perception persists that small flow-sensing devices are less accurate than volume-sensing spirometers. Objectives: To study the accuracy of spirometry performed with the MIR Spirobank (R) and to investigate how accurately

trained primary-care physicians can perform spirometry using a portable electronic spirometer. Methods: Patients with suspected occupational

asthma were submitted to specific bronchial challenge tests in the pulmonary function laboratory according to published recommendations. Serial measurements were performed with the Jaeger MasterScope device (reference standard) or the Spirobank device. Data were generated from 908 parallel measurements on 34 patients. Furthermore, 16 patients with documented moderate to severe COPD were examined in a carousel set-up by four trained physicians who each used his/her own Spirobank device coupled to a laptop computer. Results: The Spirobank spirometer performed very well compared with the Jaeger MasterScope in a laboratory environment, displaying an underestimation of the forced expiratory volume in 1 s (FEV1) and FEV1/forced vital capacity 3-deazaneplanocin A price (FVC) of 2-5%. High correlations were found for the pulmonary function parameters. The highest correlation was for FEV1 (r(2) = 0.949) and the lowest for the maximum expiratory flow at 25% of FVC (MEF25) (r(2) = 0.864). Only 2% of the observed variation in the measurement results could be explained by the type of device. Conclusions: The Spirobank

device seems to be appropriate for research purposes if the standardized protocol is used correctly and the acceptability criteria are respected. Copyright (C) 2012 S. Karger AG, Basel”
“OBJECTIVE: BKM120 To estimate the rate of vaginal implant exposure associated with biologic grafts and permanent mesh used for pelvic organ prolapse (POP) surgery, to describe treatments used for these complications, and to estimate response rates to these treatments. The secondary aims were to describe the operative and perioperative complications.

METHODS: This was a retrospective analysis of female members of Kaiser Permanente Southern and Northern California and Hawaii who underwent POP surgeries with biologic grafts and permanent mesh between September 2008 and May 2010. Inpatient and outpatient electronic medical records were reviewed for postoperative adverse events.

Comments are closed.